SSAB Boron Tube 24
Download data sheet
Download data sheet
SSAB Boron Tube 24 is a structural hollow section for hardening. It offers good workshop properties in delivery condition. The degree of hardness and toughness that can be achieved after heat-treatment will provide the final products with wear- and shock resistance properties that assure longer lifetime.
SSAB Boron Tube 24 is available at circular.
Shapes | Dimensions |
---|---|
Circular (mmin) | 139.7 - 323.95.500 - 12.75 |
Wall thickness (mmin) | 5.0 - 10.00.20 - 0.394 |
Mill length (mm) | 6000/12000 |
Other shapes, sizes and lengths are available upon request.
Outer diameter (mmin) | 5.0 mm (kg/m) | 6.0 mm (kg/m) | 8.0 mm (kg/m) | 10.0 mm (kg/m) |
---|---|---|---|---|
139.75.500 | — | 19.8 | — | — |
168.36.626 | — | 24.0 | — | — |
219.18.626 | 26.4 | 31.5 | 41.7 | 51.6 |
27310.7 | — | 39.5 | 52.3 | — |
323.912.75 | — | 47.0 | 62.3 | — |
Condition | Typical yield strength (MPa), not guaranteed |
Typical tensile strength (MPa), not guaranteed |
Typical Elongation A (%),not guaranteed |
---|---|---|---|
As delivered | 470 | 650 | 12 |
Typical mechanical properties when quenched to water:
Rp0.2 ~1100 MPa; Rm ~1400 MPa; A~8%
C (max %) |
Si (max %) |
Mn (max %) |
S (max %) |
Cr (max %) |
B (max %) |
P (max %) |
---|---|---|---|---|---|---|
0.27 | 0.30 | 1.20 | 0.010 | 0.40 | 0.0050 | 0.020 |
Characteristic | Circular hollow sections Tolerances meet or exceed the requirements of EN 10219 |
---|---|
Outside diameter (D) (1 | ±1%, with a minimum of ±0.5 mm and a maximum of ±10 mm |
Out-of-roundness | 2%, when D/T ≤ 100 |
Thickness (T) |
When D ≤ 323.9 mm: -5%/+10%, with a minimum of ±0.2 mm and maximum ±0.5 mm When 355.6 ≤ D ≤ 406.4 mm : ±10%, when T ≤ 5 mm / ±0.5 mm, when T > 5 mmWhen D > 406.4 mm : ±10%, with a maximum of ±2 mm |
Straightness | 0.20% of total length and 3 mm over any 1 m length |
Mass per unit length | Individual tube: ±6% |
Mill length | 0/+50 mm, 6000 ≤ L ≤ 12000 - 18000 mm (standard lengths 6000 & 12000 mm) |
Exact length | Agreed at the time of enquiry and order |
1) All external dimensions are measured with a minimum distance from the end of the section. The distance must be a minimum of 100 mm.